  Datasheet File OCR Text:
 Embedded Power for Business-Critical Continuity
NLP65 Series
Single, dual, and triple output
Total Power: 65 - 75W Input Voltage: 85 - 264 Vac 120 - 370 Vdc* # of Outputs: Single, dual, triple
Rev.06.02.08 NLP65 Series 1 of 4
Electrical Specifications
Special Features
* * * * * * * * * * * Universal Input 3" x 5" footprint Low profile fits 1U applications EN61000-3-2 compliance option (HCC) Overvoltage and short circuit protection 65 W with free air convection cooling EN55022, EN55011 conducted emissions level B EN61000-4-2,-3,-4, -5, -6 immunity compliant RoHS compliant LPX80 enclosure kit available 2 year warranty
Input
Input voltage range Universal input, (See Note 2) NLP65-76xx version only 120 Vac 230 Vac 120 Vac, 60 Hz 230 Vac, 50 Hz 120 Vac, with PFC 230 Vac, with PFC 120 Vac, without PFC 230 Vac, without PFC UL/IEC127 85-264 Vac 120-370 Vdc 47-63 Hz 17 A max. 32 A max. 0.7 mA 1.4 mA 1.05 A rms 0.51 A rms 1.40 A rms 0.80 A rms S3.15 A, 250 Vac In live and neutral
Input frequency range Input current (cold start) Safety ground leakage current Input current
Input fuse
Output
Total regulation (line and load) Rise time Transient response Main output Auxiliary outputs At turn-on Main output 25% step at 0.1 A/s Main outputs Cyclic operation Single and multiple 2.0% 5.0% 1.0 s, max 5.0% or 250 mV max. dev., 1ms max. recovery to 1% 0.02%/C 125%, 10% Continuous (See Note 6)
Safety
VDE0805/EN60950/IEC950 File No. 1040100-3336-0096 Licence No. 114404 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C China Compulsory Certification 60950
Temperature coefficient Overvoltage protection Short circuit protection Minimum output current
*NLP65-76xx version only
Embedded Power for Business-Critical Continuity
All specifications are typical at nominal input, full load at 25 C unless otherwise stated.
EMC Charateristics (11, 12)
Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity EN55022, FCC part 15 EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-2, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3 120 Vac, 60 Hz 230 Vac, 50 Hz 120 Vac, 65 W Input/output Input/chassis Fixed Level B Level A Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Perf. criteria 2 Perf. criteria 2 16 ms @ 65 W 78 ms @ 65 W 72% typical 3000 Vac 1500 Vac 100 kHz, 5 kHz
Rev.06.02.08 NLP65 Series 2 of 4
General Specifications
Hold-up time Efficiency Isolation voltage Switching frequency
Approvals and standards EN60950, VDE0805 (see Notes 9, 13) IEC950, UL1950, CCC60950 CSA C22.2 No. 950 Weight MTBF demonstrated 283 g (10 oz) MIL-HDBK-217F 150,000 hours min
Environmental Specifications
Thermal performance (see Notes 1, 3, 10) Operating ambient, 0 C to +70 C (See derating curve) Non-operating -40 C to +85 C 50 C to 70 C ambient, Derate to convection cooled 50% load 0 C to 50 C, ambient, 65 W convection cooled 0 C to 50 C ambient, 75 W 20 CFM forced air (See Note 10) Peak (0 C to +50 C, 60 s) See table Non-condensing Operating Non-operating 5-500 Hz per MIL-STD-810E 5% to 95% RH 10,000 feet max 30,000 feet max 2.4 G rms peak 516.4 Part IV
DERATING CURVE Output Power (Watts) 75W 20 CFM FORCED AIR COOLING 65W
NATURAL CONVECTION COOLING
38W 32W
Relative humidity Altitude Vibration (see Note 5) Shock
0C
10C 20C 30C 40C 50C 60C 70C
Embedded Power for Business-Critical Continuity
Output Voltage +5 V (IA) +12 V (IB) -12 V +5 V (IA) +15 V (IB) -15 V +5 V +24 V +12 V +5 V (IA) +24 V (IB) +5 V (IA) +12 V (IB) +5 V +12 V +15 V +24 V
Output Current Max (1) 7.5 A 2.5 A 0.65 A 7.5 A 2.2 A 0.65 A 7.0 A 1.5 A 0.7 A 7A 2A 7A 2.5 A 10 A 5.4 A 4.4 A 2.7 A Peak (3) 9.1 A 3.3 A 0.81 A 9.1 A 2.9 A 0.85 A 9.1 A 2.6 A 1.0 A 9.1 A 2.6 A 9.1 A 3.3 A 13 A 7A 5.7 A 3.5 A Fan (10) 8A 3A 0.8 A 8A 2.5 A 0.8 A 8.0 A 2.0 A 1.0 A 8A 2A 8A 3A 12 A 6.5 A 5.3 A 3.5 A Ripple (4) 50 mV 150 mV 120 mV 50 mV 150 mV 150 mV 50 mV 240 mV 120 mV 50 mV 240 mV 50 mV 150 mV 50 mV 120 mV 150 mV 240 mV
Total Non-harmonic Regulation (6) Corrected 2.0% 5.0% 5.0% 2.0% 5.0% 5.0% 2.0% 5.0% 5.0% 2.0% 5.0% 2.0% 5.0% 2.0% 2.0% 2.0% 2.0% NLP65-7605J NLP65-7612J NLP65-7615J NLP65-7624J NLP65-7629J NLP65-7620J NLP65-3322J NLP65-7610J NLP65-7608J
Harmonic Corrected NLP65-9608J
Ground Pin (12, 14, 17) NLP65-X608GJ
Rev.06.02.08 NLP65 Series 3 of 4
NLP65-9610J
NLP65-X610GJ
NLP65-9620J NLP65-9629J NLP65-9605J NLP65-9612J NLP65-9615J NLP65-9624J
NLP65-X620GJ NLP65-X629GJ NLP65-X605GJ NLP65-X612GJ NLP65-X615GJ NLP65-X624GJ
Notes
Natural convection cooling. Models NLP65-X629J, NLP65-X608J, NLP65-X610J must not exceed 62.5 Watts continuous output power with natural convection. Model NLP65-X620J not to exceed 65 Watts continuous output power with natural convection. Model NLP65-3322J must not exceed 60 Watts continuous output power with natural convection. 2 When the input voltage is less than 90 Vac the operating temperature range is 0 C to +40 C. The ripple and regulation specifications may not be met. 3 Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total regulation limits. 4 Figure is peak-to-peak for convection power rating. Output noise measurements are made across a 20 MHz bandwidth using a 6 inch twisted pair, terminated with a 10 F electrolytic capacitor and a 0.1 F ceramic capacitor. 5 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5 Hz to 500 Hz. 6 A minimum load on the main output is required for proper start up. For multiple outputs and single +5V output, the minimum load on the +5 V is 0.2 A. For single outputs greater than +5 V the minimum load is 0.1 A. To maintain stated regulation then: for single output units I 0.2 A for multiple output units 0.25 I(A)/I(B) 5, for I(A) 0.2 A. 7 For optimum reliability, no part of the heatsink should exceed 120 oC, and no semiconductor case temperature should exceed 130 oC. 8 CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. 9 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 10 Maximum continuous output power for all multiple output models must not exceed 75 Watts (70 watts for NLP65-3322J)with 20 CFM forced air cooling. 1 11 Conducted and radiated emissions testing were performed using the standard EN55022 set-up with a stand alone NLP65 unit placed on a grounded metal plate with a line choke on the AC input and ground wires (i.e. the wires are looped through an EMI suppression toroid). For system compliance it is usually necessary to install an `off-the-shelf' AC inlet with an integral line filter in the system chassis or to install a line choke on the input wires as close as possible to AC entry point of the system chasssis. Please contact the applications group at Artesyn for assistance with EMI compliance. 12 The NLP65 units with the suffix `G' is the ground pin and ground choke option. J2, L6 and JP10 are included. J2 is a safety agency approved grounding pin, L6 is a ground choke and JP10 is a jumper. This option is intended for use in nonmetallic chassis applications where grounding is not possible via the mounting screws. The ground choke is provided to assist system EMC compliance. When performing conducted emissions testing on stand alone units, the `G' option is required to meet level B. To order simply add the suffix `G' to the standard model number, e.g. NLP65-7608GJ, NLP65-9608GJ. This option is available for both the PFC and non-PFC versions. 13 All models require a minimum mounting stand-off of 0.25 inches (6.35 mm) in the end use product. 14 The NLP65-9608J is available with an enclosure. To order an enclosed version, see model numbering options below. 15 No PFC version, EN61000-3-2 is not applicable to this model. 16 The `J' suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. 17 NOTICE: Some models do not support all options. Please contact your local Emerson Network Power representative or use the on-line model number search tool at http://www.powerversion.com.
Model Numbering Options
1 2 3 The enclosure version includes: IEC connector, on/off switch, wire harness output connector and fitted cover. To order, please add the suffix `E' the model number, e.g. NLP65-9608EJ. See NLP65 enclosure for details. A Safety earth ground pin and ground choke are available as an option. To order, please add the suffix `G' the model number, e.g. NLP65-X608GJ. To order an enclosure kit (unfitted), order the part number LPX80.
Embedded Power for Business-Critical Continuity
Americas Mechanical Drawing
5.00 (127.00) 4.550 (115.57) 0.225 (5.715)
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 (760) 930 4600 Facsimile: +1 (760) 930 0698
Rev.06.02.08 NLP65 Series 4 of 4
Europe (UK)
J1 3 1 N L 2.550 (64.770) J3 1
3.00 (76.20) J2 C19 T1
6
Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888
MAXIMUM COMPONENT HEIGHT 1.26 (32.00) TOLERANCE: .xxx .xx 0.005" 0.02"
Mounting Hole Diameter 0.156 (4.00)
For global contact, visit:
ALL DIMENSIONS IN INCHES (mm)
www.powerconversion.com technicalsupport@ powerconversion.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
Emerson Network Power. The global leader in enabling business-critical continuity.
INPUT PIN CONNECTIONS J1 Pin 1 AC Line Pin 2 No Pin Pin 3 AC Neutral J2 (ON `G' SUFFIX ONLY) Pin 1 Safety Ground Input and output connectors
AC (J1) connector type Molex 26-60-4030 type. DC (J3) connector type Molex 26-60-4060 type.
Mating connectors
AC (J1) mating connector type Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp terminals. DC (J3) mating connector type Molex 09-50-3061 with Molex 2478 phosphor bronze crimp terminals or equivalent.
AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower. com
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. (c)2008 Emerson Electric Co.
Note: The input and output connectors are the same as those used on NFS40, NFN40, NAL40, NAN40 and NLP40.
J3 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6
OUTPUT PIN CONNECTIONS SINGLE DUAL V (A) V (A) V (A) Return Return Return V (B) V (A) V (A) Return Return N/C
TRIPLE V (B) V (A) V (A) Return Return V (C)


▲Up To Search▲   

 
Price & Availability of NLP65-3322J

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X